NOC Safar247

Ticket Number Company Country Date and Time Priority Site Code User Notes Requestor
SFR-00009475 Meta 2025-03-05 18:18:00 LOW SYD2 Scope of work: Scope of Work #1: Troubleshoot Network Equipment The Smart Hands is required to call our team on +1 650 308 7200 Press 1 before starting any onsite activity. ===== Need to troubleshoot the circuit at pr04.syd2:et-1/0/19. PPP:0427:1216421 (SY4:02:060200:0427:RU44:5A:01-12) 1. Check the span 2. Clean the fiber and all physical connections in the span between devices 3. Reseat the optics 4. Measure the TX/RX light levels at the router port & patch - If necessary provide loop to find the segment where the errors are increasing - Swap the optics/sfp if required. Spares are in our storage cabinet. ===== name = pr04.syd2.tfbnw.net serial_number = DM385 asset_tag = 2770640 suite = SY4:02:060200 row = 4 rack = 03 rack_position = 01 Meta reference number: nwt20026063 Bruno daSilva
SFR-00009474 Meta 2025-03-05 17:11:00 LOW T217019654 SOW: Before proceeding with activity, please contact engineer Domingo, +6597814274 1 - Insert 8 x XDR4 (FR1) 100G SFPs 2 - Lay 16 Cables from ROUTER to ODF 3 - Loopback test if needed 4 - Label the cables. 5 - See the attached port mapping.  Domingo Ramant
SFR-00009473 Meta 2025-03-05 15:39:00 LOW MNL1 Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer. Scope of work: Scope of Work #1: Troubleshoot Network Equipment SH should call us on +16503087200 and press option 1 before the activity and mention Meta ref ticket so that we can troubleshoot together: SH is to check pr02.mnl1:et-1/0/28:0 1. Check the span, Clean the fiber and all physical connections (ie bulkheads) in the span between devices 2. Reseat the optics 3. Measure the TX/RX light levels at the router port, patch, and demarcation 4. Provide loop to find the segment where the errors are increasing 5. Swap the optics/sfp if required. Spares are in our storage cabinet (if required) 6. Share the picture of the faulty SFP link Meta reference number: nwt20063744 Prem Anand Arul Prakash
SFR-00009472 Meta 2025-03-05 12:55:00 HIGH TPE1 Start Date: 2025-03-06 09:00 End Date: 2025-03-06 10:00 Smijin Francis
SFR-00009471 Meta 2025-03-04 21:46:00 HIGH HKG1 tart Date: 2025-03-05 10:00 End Date: 2025-03-05 11:00 Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer. Scope of work: Scope of Work #1: Troubleshoot Network Equipment SH is to Check the span, clean the fiber and all physical connections in the span between devices - Reseat the optics - Measure the TX/RX light levels at the router port, patch, - If necessary provide loop to find the segment where the fault is - Swap the optics if required. Spares are in our storage cabinet. =============================================================== name = psw03.hkg1.tfbnw.net datacenter = hkg1 suite = 2203B row = 7 rack = 07 rack_position = 03 serial_number = FGN231505NA asset_tag = DI01068 make = Arista Networks model = DCS-7280DR3AK-54-F ================================================= name = msw1al.02.hkg1.tfbnw.net datacenter = hkg1 suite = 2203B row = 8 rack = 22 rack_position = 42 serial_number = FOC2536N3LH asset_tag = 10196971 make = Cisco model = 8201 ======================================================= psw03.hkg1:Ethernet3/1 msw1al.02.hkg1:HundredGigE0/0/0/6 Meta reference number: nwt20070034 Alan McDermott
SFR-00009470 Other 2025-03-04 17:51:00 LOW Request from EURUS Schedule: 06-Feb-2025, 02:00 AM or 07-Feb-2025, 02:00 AM Local Time. Krishna Chaudhary
SFR-00009469 Meta 2025-03-04 16:37:00 HIGH HKG4 Start Date: 2025-03-07 03:00 End Date: 2025-03-07 05:00 Louie Aquino Castro
SFR-00009468 Meta 2025-03-04 15:04:00 LOW HKG4 Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer. Scope of work: Scope of Work #1: Unknown The Smart Hands is required to call our team on +1 650 308 7200 Press 1 before starting any onsite activity and refer to ou rnwt20038985 SH to collect RMA's from inbound and call out hotline for replacement guidelines. Meta reference number: nwt20038985 The inbound logistics reference number for this RMA is Please acknowledge this request and update the smart hands details Thank you for your attention on this case and you may contact us for any further clarification. Bennet Joseph
SFR-00009467 Meta 2025-03-04 14:58:00 LOW XSP1 Start Date: 2025-03-06 09:00 End Date: 2025-03-06 17:00 Vernon Kwa
SFR-00009466 Meta 2025-03-04 12:57:00 HIGH SIN6 Start Date: 05 Mar 2025 End Date: 05 Mar 2025 Time: 09:00am-11:00am lcoal time Domingo Ramant

🎟️ Ticket Dashboard - 2026

Total Tickets

1029

July Tickets

29