Ticket Number Company Country Date and Time Priority Type of Service Site Code User Notes
SFR-00009676 Meta Singapore 2025-04-17 10:16:00 LOW SIN2 Anis Meta Site ID: SIN2
Date and Time (Site Local Time): 2025-04-23 10:30 AM
Requestor Name and Contact: Kin Hoe Wong @+65 8198 2503
SFR-00009675 Meta Malaysia 2025-04-17 23:53:00 LOW KUL2 Nabil Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
Call IPBB on 650-308-7200 option 1. Reference ticket nwt20500450

Span down between:

dcnsw09.kul2:ge-0/0/3 | ap-my-kul2-1-6:COLAN-6-X

1. Check the span, Clean the fiber and all physical connections (i.e. bulkheads) in the span between the two devices and look for breaks/bends using a visual fault locator.
2. Install hard loop directly on port to prove out hardware
3. Install hard loop directly on Fiber-jumper to prove out fiber cable
4. Reseat/Replace the Optics/Fiber-jumper (Spares are located in our storage cabinet)

name = [dcnsw09.kul2.tfbnw.net](http://dcnsw09.kul2.tfbnw.net)
serial_number = NX0218410155
asset_tag = 2769832
suite = 11F-C
row = 2
rack = 02
rack_position = 21
ap-my-kul2-1-6:COLAN-6-X
Suite 11F-C
Row 2
Rack 02

Please ensure you bring the following:


- Fiber Scope
- Fiber cleaning kit to include Port Cleaning tool
- Multi length SMF fiber jumpers should we need to replace
- Red light source for tracing fiber
- MPO/QSFP Tools
- Light meter
- Volt Meter

Please acknowledge the request and update us as soon as possible. Thanks.

Please note: upon completing work and prior to leaving site, please confirm all aisle containment doors are closed. This prevents heat from recirculating into rack intakes and is crucial to preventing thermal overload and potential shutdown/downtime due to overheating events.


Meta reference number: nwt20500450
SFR-00009674 Meta Hong Kong 2025-04-16 21:40:00 LOW HKG4 Syima Start Date: 2025-04-21 10:00
End Date: 2025-04-21 11:00
SFR-00009673 Meta Malaysia 2025-04-16 21:22:00 LOW KUL2 Syima Start Date: 2025-04-22 09:00
End Date: 2025-04-22 12:00
SFR-00009672 Meta Singapore 2025-04-16 19:21:00 LOW SIN11 Nabil Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
Link down between oobas01.sin11:xe-0/0/2:2-oobsw03.sin11:xe-0/2/0, please check full path, optics, fiber, etc ...

name = oobas01.sin11.tfbnw.net

datacenter = sin11

suite = SG5:06:020300

row = 5

rack = 01

rack_position = 26

serial_number = EV546

asset_tag = 5895990

make = Juniper Networks

model = QFX10002-36Q

status = IN_USE

fb_part_number = 20-001809

**

name = oobsw03.sin11.tfbnw.net

datacenter = sin11

suite = SG5:06:020300

row = 1

rack = 04

rack_position = 42

serial_number = NX0219150327

asset_tag = 2770171

make = Juniper Networks

model = EX3400-48T

status = IN_USE

fb_part_number = 20-002050
Meta reference number: nwt20498434
SFR-00009671 Meta Singapore 2025-04-16 19:21:00 LOW SIN11 Nabil Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
name = oobsr01.sin11.tfbnw.net

datacenter = sin11

suite = SG5:06:020300

row = 5

rack = 01

rack_position = 28

serial_number = DB3917AK9165

asset_tag = 3385393

make = Juniper Networks

model = SRX1500-SYS-JB-AC

name = oobas02.sin11.tfbnw.net

datacenter = sin11

suite = SG5:06:020300

row = 5

rack = 02

rack_position = 26

serial_number = DU495

asset_tag = 5088116

make = Juniper Networks

model = QFX10002-36Q

oobsr01.sin11:xe-0/0/19 oobas02.sin11:xe-0/0/0:0

The technician will be required to troubleshoot a circuit which is down. This may involve placing loops on fiber/ports, tracing, cleaning or swapping cables or SFPs, taking light measurements, updating labels.

Please call on the number provided and then select option 1 for ENS Breakfix prior to the commencement of any intrusive works.
Meta reference number: nwt20498278
SFR-00009670 Meta Philippines 2025-04-16 08:10:00 LOW MNL3 Zul Start Date: 2025-04-17 10:00
End Date: 2025-04-17 14:00
SFR-00009669 Meta Taiwan 2025-04-16 02:23:00 LOW TPE5 Nabil Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
#COA:

1. Tech to call IPBB (+1-650-308-7200 opt. 1) prior to any work being done.

2. We request a smart hands to investigate an issue with missing power:

3. Visually check for any recent changes in the rack or suite

4. The Remote Hands is also requested to take electrical testing equipment, include a volt meter.

"name": "msw1fe.50.tpe5.tfbnw.net",

"suite": "8F_CAGE1",

"row": "5",

"rack": "05",

"rack_position": "42",

"datacenter": "tpe5"
Meta reference number: nwt20445495
SFR-00009668 Meta Australia 2025-04-15 14:43:00 SYD2 Zul Meta Site ID: SYD2
Date and Time (Site Local Time): 2025-04-16 11:00 AM
SFR-00009667 Meta Philippines 2025-04-15 13:54:00 LOW MNL3 Zul Start Date: 2025-04-16 09:00
End Date: 2025-04-16 14:00