Ticket Number Company Country Date and Time Priority Type of Service Site Code User Notes
SFR-00009371 Meta Hong Kong 2025-02-10 15:36:00 LOW HKG4 Syima Start Date: 12 Feb 2025
End Date: 12 Feb 2025
Time: 10:00am-02:00pm local time
SFR-00009369 Meta Malaysia 2025-02-10 14:46:00 LOW SIN9 Nabil
SFR-00009370 Meta Malaysia 2025-02-10 14:45:00 LOW KUL2 Zul Start Date: 2025-02-12 10:01
End Date: 2025-02-12 11:00
SFR-00009368 Meta Philippines 2025-02-10 10:06:00 LOW MNL3 Zul Start Date: 2025-02-11 09:00
End Date: 2025-02-11 17:00
SFR-00009367 Meta New Zealand 2025-02-10 02:57:00 HIGH AKL1 Syima
SFR-00009366 Meta Philippines 2025-02-09 13:41:00 HIGH MNL1 Nabil Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
SH should call us on +16503087200 and press option 1 before the activity and mention Meta ref ticket so that we can troubleshoot together:

SH is to check msw1av.02.mnl1.tfbnw.net physical status of the device and report it to SH

1. Check the span, Clean the fiber and all physical connections (ie bulkheads) in the span between devices

2. Reseat the optics

3. Measure the TX/RX light levels at the router port, patch, and demarcation

4. Provide loop to find the segment where the errors are increasing

5. Swap the optics/sfp if required. Spares are in our storage cabinet (if required)

6. Share the picture of the faulty SFP link

name = msw1av.02.mnl1.tfbnw.net

datacenter = mnl1

suite = L5M01CAGE01

row = 5

rack = 15

rack_position = 42

serial_number = FOC2645P311

asset_tag = 12702406

make = Cisco
Meta reference number: nwt19846001
SFR-00009365 Meta Singapore 2025-02-09 07:46:00 LOW XSP1 Nabil SITE: XSP1
Start Date: 2025-02-10 12:00
End Date: 2025-02-10 14:00

Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
Call IPBB on 650-308-7200 option 1. Reference ticket nwt19845465

1. Check the span, Clean the fiber and all physical connections (i.e. bulkheads) in the span between the two devices and look for breaks/bends using a visual fault locator.
2. Install hard loop directly on port to prove out hardware
3. Install hard loop directly on Fiber-jumper to prove out fiber cable
4. Reseat/Replace the Optics/Fiber-jumper (Spares are located in our storage cabinet)
5. Measure the TX/RX light levels at the router port, patch, and demarcation

Please ensure you bring the following:

- Fiber Scope
- Fiber cleaning kit to include Port Cleaning tool
- Multi length SMF fiber jumpers should we need to replace
- Red light source for tracing fiber
- MPO/QSFP Tools
- Light meter
- Volt Meter

Please acknowledge the request and update us as soon as possible. Thanks.

Please note: upon completing work and prior to leaving site, please confirm all aisle containment doors are closed. This prevents heat from recirculating into rack intakes and is crucial to preventing thermal overload and potential shutdown/downtime due to overheating events.


Location:
name = dcncs05.xsp1.tfbnw.net
serial_number = 131542318
asset_tag = 5267550
suite = F5SC01
row = 3
rack = 01
rack_position = 40
make = ZPE Systems
model = NSC-T48R-STND-DAC-SFP

Meta reference number: nwt19845465
SFR-00009364 Meta Australia 2025-02-09 05:01:00 LOW SYD3 Nabil SITE: SYD3
Start Date: 2025-02-13 08:00
End Date: 2025-02-13 12:00

Details of Request: Before starting any onsite activity, the attending engineer should call ENS OPS NETWORK BREAKFIX on +1 6503087200 option 1 and mention the Meta reference number associated to each scope of works to work together with a Meta engineer.

Scope of work:
Scope of Work #1: Troubleshoot Network Equipment
Call IPBB on 650-308-7200 option 1. Reference ticket nwt19844878

Investigate cable connection between gsw02.syd3:Ethernet8/1 msw1ay.50.syd3:HundredGigE0/0/0/1

1. Locate both devices.
2. Once Meta tech is ready to move forward investigate cabling between the two devices and their correlating ports.
3. Reseat cables if necessary/ Replace cables if necessary
4. Work with Meta tech to confirm next steps.

name = gsw02.syd3.tfbnw.net
serial_number = JPE21102403
asset_tag = 6117029
suite = 2X
row = 4
rack = 01
rack_position = 36


name = msw1ay.50.syd3.tfbnw.net
serial_number = FOC2536N3LL
asset_tag = 12697460
suite = 2X
row = 4
rack = 13
rack_position = 42

Meta reference number: nwt19844878
SFR-00009363 Meta Singapore 2025-02-07 22:24:00 LOW SIN11 Anis Start Date: 2025-02-10 09:00
End Date: 2025-02-10 10:00
SFR-00009362 Meta Hong Kong 2025-02-07 18:07:00 LOW HKG4 Anis Date : [2025-02-10]
Time : [9:00 AM]
Timezone : [HKT]